# CN105 Compatibility: Check Your Model

> Type your Mitsubishi mini-split model number and instantly see if it works with the Serin Controller. Wall-mount, ducted, floor, and cassette models covered.

Source: https://serin-labs.com/compatibility.html
Last updated: 2026-11-19

Type the model number of your indoor unit to see whether it is compatible.

The instant checker requires JavaScript. The same information is in the list and FAQ below.

## Before you order

1. **Check the model number.** It is on a label on the indoor unit, usually on the right side behind the front panel. Enter it in the checker above, even if you have already found a CN105 port: on a few series the connector is fitted but the unit does not support control through it.
2. **Look for the CN105 port.** Open the front panel and locate the main control board. The CN105 port is a small 5-pin connector (usually red, sometimes white) labeled "CN105" on the PCB. See the [wiring reference](https://serin-labs.com/wiring.html) for what it looks like.
3. **Check that the port is available.** The controller cannot share CN105 with another accessory, such as an MHK1 or MHK2 wireless thermostat, a Mitsubishi Wi-Fi adapter, or a wall-controller interface. An accessory on CN105 has to be unplugged, and CN105 splitters are not supported. A wall controller connected directly to separate indoor-unit terminals needs a [different compatibility check](https://serin-labs.com/controller/install.html#wired-controls). The handheld infrared remote does not use CN105 and is unaffected.

## What is not compatible

The following systems are not compatible, even if a similar connector is present.

Mitsubishi *Heavy Industries*

SRK · SRC · SRF

A different company from Mitsubishi Electric. These units use a different protocol and have no CN105 connector.

Air-to-water heat pumps

Ecodan · Zubadan · Geodan

The connector is there but the serial protocol differs. See [Mitsubishi-CN105-Protocol-Decode](https://github.com/m000c400/Mitsubishi-CN105-Protocol-Decode) for Ecodan-specific projects.

No usable CN105

pre-2006 · MSZ-HJ · MSH-BF · LGH · MSZ-ZF

Pads without a connector, or no port at all. Soldering is possible on MSZ-HJ but not recommended. Lossnay (LGH) ventilators use a different protocol.

## Common questions

**I found a CN105 port. Is my unit compatible?**

Usually, but the port alone does not confirm compatibility. Most Mitsubishi Electric indoor units with a CN105 connector use the serial protocol supported by this controller.

The exceptions are **MSY/MSZ-A**, **MSZ-FD**, **MSZ-HE** and **MS-WA**, plus unsupported trims of MSZ-D, MSZ-FE, MSY/MSZ-GE and SEZ-KD. Some of these control boards have a CN105 connector that is not enabled for control, so check both the model number and the port.

**Something is already plugged into my CN105 port**

The existing CN105 accessory must be disconnected because the controller requires exclusive use of that port. This includes a Wi-Fi adapter, an MHK1/MHK2 receiver, or a wired-controller interface connected there. CN105 splitters are not supported.

A wall controller wired directly to separate indoor-unit terminals, such as TB15, is a different arrangement; check the [wall-controller connection guide](https://serin-labs.com/controller/install.html#wired-controls). The handheld infrared remote does not use CN105 and continues to work.

**My unit has CN110 but not CN105. Will it work?**

CN110 is used by Mitsubishi's Wi-Fi adapter for MELCloud or Kumo Cloud. It is **separate from CN105**. Many newer indoor units have both ports: CN110 for the factory Wi-Fi module and CN105 for additional serial communication. Look for CN105 elsewhere on the control board. An indoor unit with CN110 but no CN105 is not compatible with this controller.

**My unit has CN100 instead of CN105**

Some older City Multi (VRF) indoor units have CN100 instead of CN105. You can use a Mitsubishi **PAC-IT51AD-E** or **PAC-IT52AD-E** signal adapter to convert CN100 to a CN105-compatible interface. These adapters are not interchangeable; check which one your unit requires.

**I have a multi-zone system. Does it work?**

Yes. Each indoor head in a multi-zone system has its own CN105 port. You need **one controller per indoor unit**. The outdoor unit (MXZ series) does not need a controller.

Note: some advanced sensors like compressor frequency and outside air temperature may not be available when multiple indoor units share a single outdoor unit.

**My model is not on any list. Can I try it anyway?**

If the model is not listed, first confirm that the Mitsubishi Electric indoor unit has a CN105 port. Most units with this port use the supported serial protocol, but a few exceptions are listed above. Test compatibility before relying on the controller, and [report a successful result on Discord](https://discord.gg/cC2ybSQDZd) to help other owners.

**I have a Trane or American Standard heat pump**

Many Trane and American Standard ductless systems are rebranded Mitsubishi Electric units. Wall-mounted models starting with **NAXWST**, **NTXWPH**, **NTXWST**, **NTYWST**, **NTXWMT**, or **NTXWEL** are compatible, and so are the **NTXCKS**, **NTXUKS**, **NTXDKS**, **NTXFKS**, and **NTXAMT** cassette, ducted, floor, and air-handler units. Trane's commercial models start with **TP**, and the checker above answers each one with the verdict of the Mitsubishi model it is built from. Models starting with **NTXS**, **NTYS**, or **NTXM** (including NTXMPH) are outdoor units, so check the indoor unit instead.

**What do the regional model suffixes mean?**

Mitsubishi Electric uses different model suffixes by region for the same hardware. The regional suffix does not affect CN105 compatibility; the same unit series is compatible across all regions.

| Region | Suffix pattern | Examples |
| --- | --- | --- |
| North America (R410A) | -NA, -NA-U1 | MSZ-GL09NA, MSZ-EF15NAW-U2 |
| North America (R454B) | -NL | MSZ-GX12NL, MSZ-FX15NL |
| Europe (R32) | -VG, -VGK, -VG2 | MSZ-AP25VGK, MSZ-LN35VG2W |
| Europe (R410A) | -VE, -VA, -VF | MSZ-SF35VE3, MSZ-HR35VF |
| Australia / NZ | -VGD, -VGKD, -VAD | MSZ-AP35VGD, MSZ-GE25VAD |
| Asia / Singapore | -VE, -VG (MSXY prefix) | MSXY-FN10VE, MSXY-FP13VG |

## Browse by indoor unit type

Select a type to view its compatibility list.

Wall-mounted MSZ · MSY · MSXY some trims are suffix-dependent Floor-mounted MFZ · SFZ verify CN105 on KT Ceiling cassette MLZ · SLZ all confirmed Ducted & air handlers SEZ · SVZ · MVZ · PEAD · PEY · PVA NA SEZ-KD and PEAD-A are suffix-dependent; other SEZ-KD need a 9600 baud setting P-Series PKA · PCA · PLA · PEA · PEAD · PAA · PVA most NA trims are suffix-dependent; PEA-RP needs a 9600 baud setting CITY MULTI / S / Y / R2 / HVRF PCFY · PDFY · PEFY · PFFY · PKFY · PLFY · PMFY · PVFY · PWFY exact table-first LinkDrive audit Trane / American Standard rebranded NAXWST · NTXW · NTYW · NTXCKS · NTXDKS · TPKA · TPLFYP same Mitsubishi hardware inside

## Compatible indoor units

The list below covers residential, P-Series, CITY MULTI, S-Series, Y-Series, R2-Series, and HVRF indoor units. Compatibility can change with the complete model suffix, especially in CITY MULTI families, so match the full label rather than the family prefix alone. As a general indicator, indoor units that support **Kumo Cloud** in North America or **MELCloud** elsewhere have a CN105 port.

Every model number in the US catalogs of Mitsubishi Electric and Trane is in the [full indoor unit list](https://serin-labs.com/models/indoor.html).

**Wall-mounted**

| Series | Examples & notes | Verdict |
| --- | --- | --- |
| MSZ-FX, MSZ-GX, MSZ-HX, MSZ-WX, MSZ-EX, MSZ-JX | MSZ-FX15NL MSZ-GX12NL · NA (R454B) · Newest 2025 low-GWP models | Compatible |
| MSZ-FS | MSZ-FS06NA MSZ-FS09NA MSZ-FS12NA MSZ-FS18NA · NA · Widely confirmed | Compatible |
| MSZ-GS | MSZ-GS06NA MSZ-GS09NA MSZ-GS12NA MSZ-GS15NA · NA · Widely confirmed | Compatible |
| MSZ-GL | MSZ-GL06NA MSZ-GL09NA MSZ-GL12NA MSZ-GL15NA MSZ-GL18NA MSZ-GL24NA · NA, AU · Widely confirmed | Compatible |
| MSZ-FH | MSZ-FH06NA MSZ-FH09NA MSZ-FH12NA MSZ-FH15NA MSZ-FH18NA · NA, EU · Widely confirmed; Hyper-Heat | Compatible |
| MSZ-EF | MSZ-EF09NA MSZ-EF15NA MSZ-EF25VGK MSZ-EF42VE · NA, EU · Designer series | Compatible |
| MSZ-AP | MSZ-AP20VGK MSZ-AP25VGK MSZ-AP35VGD MSZ-AP50VGK · EU, AU/NZ · Widely confirmed | Compatible |
| MSZ-AY | MSZ-AY20VGK MSZ-AY25VGK MSZ-AY35VGK MSZ-AY50VGK · EU · Confirmed | Compatible |
| MSZ-LN | MSZ-LN25VG2 MSZ-LN35VGW MSZ-LN50VG2W · EU, NZ · Kirigamine Style; some have built-in Wi-Fi on CN110 — CN105 is separate and available | Compatible |
| MSZ-HR | MSZ-HR25VF MSZ-HR35VF MSZ-HR45VF MSZ-HR50VF · EU · Widely confirmed | Compatible |
| MSZ-SF | MSZ-SF25VE MSZ-SF35VE3 MSZ-SF50VE3 · EU · Confirmed | Compatible |
| MSZ-YK | MSZ-YK18VA · EU/Asia · Confirmed via owner report | Compatible |
| MSZ-FN | MSZ-FN06NA · NA · Confirmed via owner report | Compatible |
| MSZ-BT, MSZ-DM, MSZ-RW, MSZ-FT, MSZ-GF, MSZ-WR, MSZ-HM, MSZ-JP | MSZ-BT MSZ-DM MSZ-RW MSZ-FT MSZ-GF MSZ-WR MSZ-HM MSZ-JP · Various · All confirmed via Kumo Cloud / MELCloud / community reports | Compatible |
| MSZ-FE | MSZ-FE09NA-8 has CN105 MSZ-FE12NA-8 has CN105 MSZ-FE18NA has CN105 MSZ-FE09NA no CN105 MSZ-FE12NA no CN105 · NA · 09/12NA-8 and 18NA have CN105; base 09/12NA (no suffix) does not, per Mitsubishi's official M-Series controls compatibility table | Check suffix |
| MSZ-GE, MSY-GE | MSZ-GE25VA has CN105 MSZ-GE09NA-8 has CN105 MSZ-GE24NA has CN105 MSZ-GE06NA no CN105 MSZ-GE09NA no CN105 MSZ-GE12NA no CN105 MSZ-GE15NA no CN105 MSZ-GE18NA no CN105 · NA, EU/Asia · EU/Asia VA-suffix trims (e.g. MSZ-GE25VA) confirmed via owner report. NA is suffix-dependent: NA-8, NA-9, and GE24NA have CN105; base 06–18NA (no suffix) does not, per Mitsubishi's official M-Series controls compatibility table | Check suffix |
| MSZ-D, MSY-D | MSZ-D…NA-8 has CN105 MSZ-D…NA no CN105 · NA · Only the -NA-8 suffix has CN105; base -NA models do not, per Mitsubishi's official M-Series controls compatibility table | Check suffix |
| MSY (cooling-only) | MSY-GL09NA MSY-GE10VA MSY-GX18NL · NA, Asia · Same control board as MSZ equivalents, so the same caveats apply: MSY-GL and MSY-GS are compatible, MSY-D and MSY-GE are suffix-dependent (see the rows above), and MSY-A has no CN105 | Compatible |
| MSXY (Asia-Pacific) | MSXY-FN10VE MSXY-FN13VE MSXY-FP10VG · Singapore, Asia · Starmex-branded; confirmed | Compatible |
| MSZ-FD | MSZ-FD · Marked "NO" in the CN105 Remote Controllers, Interfaces, and Accessories row of Mitsubishi's official M-Series controls compatibility table | Not compatible |
| MSZ-HE | MSZ-HE · Marked "NO" in the CN105 Remote Controllers, Interfaces, and Accessories row of Mitsubishi's official M-Series controls compatibility table | Not compatible |
| MSZ-A, MSY-A | MSZ-A MSY-A · Marked "NO" in Mitsubishi's official M-Series controls compatibility table. Some of these units do have a CN105 connector fitted, but it isn't wired for control — the port being there doesn't make the unit work | Not compatible |
| MS-WA, MSZ-WA | MS-WA MSZ-WA · Marked "NO" in the CN105 Remote Controllers, Interfaces, and Accessories row of Mitsubishi's official M-Series controls compatibility table (listed as MSZ-WA in the 2026 chart, MS-WA in earlier revisions) | Not compatible |

**Floor-mounted**

| Series | Examples & notes | Verdict |
| --- | --- | --- |
| MFZ-KX (R454B), MFZ-KJ, MFZ-KA | MFZ-KA09NA MFZ-KJ18NA · MFZ-KA and MFZ-KJ confirmed on Mitsubishi's official M-Series controls compatibility table | Compatible |
| MFZ-KT | MFZ-KT25VG MFZ-KT35VG · Some MFZ-KT models report CN104 only — verify CN105 is present | Check CN105 |
| SFZ-M | SFZ-M25VA SFZ-M35VA SFZ-M50VA SFZ-M60VA SFZ-M71VA · EU · Concealed floor-standing; CN105 confirmed via the service manual and support for the MAC-597IF-E interface, which connects to CN105 | Compatible |

**Ceiling cassette**

| Series | Examples & notes | Verdict |
| --- | --- | --- |
| MLZ-KX (R454B), MLZ-KP, MLZ-KY, MLZ-KA | MLZ-KP09NA MLZ-KP12NA MLZ-KP18NA MLZ-KA50VA · MLZ-KP and MLZ-KY confirmed on Mitsubishi's official M-Series controls compatibility table; horizontal vane not available on all models | Compatible |
| SLZ-AF (R454B), SLZ-KA, SLZ-KF | SLZ-KA12NA SLZ-KF35VA SLZ-M50FA · Four-way cassette; SLZ-AF, SLZ-KA and SLZ-KF confirmed on Mitsubishi's official M-Series controls compatibility table | Compatible |

**Ducted & air handlers**

| Series | Examples & notes | Verdict |
| --- | --- | --- |
| SEZ-AD (R454B), SEZ-M | SEZ-M50DAL · Confirmed; SEZ-AD has CN105 on Mitsubishi's official M-Series controls compatibility table | Compatible |
| SEZ-KD (NA) | SEZ-KD09NA4 has CN105 SEZ-KD12NA4R1 has CN105 SEZ-KD09NA no CN105 · NA · Suffix-dependent: NA4 and NA4R1 have CN105, base NA (no suffix) does not, per Mitsubishi's official M-Series controls compatibility table | Check suffix |
| SEZ-KD (VA, VAL, VAQ) | SEZ-KD25VAQ SEZ-KD35VAL SEZ-KD71VA · EU, AU, Asia · Has CN105 and answers at 9600 baud instead of 2400. On HomeKit-compatible and Matter-compatible firmware, set CN105 Baud Rate to 9600 under Device > Advanced in the web interface. On ESPHome, set baud_rate to 9600 in the uart block of your YAML | Compatible |
| SVZ-AP (R454B), SVZ-KP, MVZ-A | SVZ-KP18NA SVZ-KP24NA SVZ-KP36NA MVZ-A24AA4 MVZ-A30AA7 · Multi-position air handler; confirmed. SVZ-AP, SVZ-KP and both MVZ trims (AA4 and AA7) have CN105 on Mitsubishi's official M-Series controls compatibility table | Compatible |
| PEAD-NL (R454B), PEAD-M, PEAD-RP, PEAD-SP | PEAD-M100JAAR1 PEAD-RP100EA2 · Mid-static ducted; confirmed. Some models have quirks. | Compatible |
| PEY-M | PEY-M50JAL2 PEY-M60JAL2 PEY-M80JAL2 PEY-M100JAL2 PEY-M125JAL2 · Asia · Cooling-only version of PEAD-M; has CN105 | Compatible |
| PEAD-A (NA) | PEAD-A…AA4/AA5/AA7/AA8 has CN105 PEAD-A…AA no CN105 · North American AA trims are suffix-dependent: AA4, AA5, AA7 and AA8 have CN105, the base AA does not, per Mitsubishi's official P-Series controls compatibility table | Check suffix |
| PVA-NL (R454B), PVA-A | PVA-A18AA7 PVA-A36AA7 PVA-A42AA7 · Multi-position air handler; confirmed | Compatible |

**P-Series**

| Series | Examples & notes | Verdict |
| --- | --- | --- |
| PKA (wall-mounted) | PKA-A…LA/AL/AK has CN105 PKA-A…HA4/HA6/HA7 has CN105 PKA-A…KA4.TH/KA6/KA7/KA8 has CN105 PKA-A…FA no CN105 PKA-A…GA no CN105 PKA-A…HA/HAL no CN105 PKA-A…KA.TH no CN105 · The LA, AL and AK trims, HA4 and later, and KA4 and later have CN105; the FA, GA, base HA/HAL and base KA.TH trims do not, per Mitsubishi's official P-Series controls compatibility table | Check suffix |
| PKA-A24/A30/A36KAL.TH | PKA-A24KAL.TH PKA-A30KAL.TH PKA-A36KAL.TH · The official table does not name the KAL.TH revision precisely, and its LinkDrive Controls page lists none of the qualifying controls | Check CN105 |
| PCA (ceiling-suspended) | PCA-A…KA4/KA5/KA6/KA7/KA8 has CN105 PCA-A…AK has CN105 PCA-A…GA no CN105 PCA-A…KA no CN105 · KA4 through KA8 and the AK trim have CN105; the GA and base KA trims do not, per Mitsubishi's official P-Series controls compatibility table | Check suffix |
| PCA-A42KA5.TH | PCA-A42KA5.TH · Its LinkDrive Controls page lists the qualifying CN105 controls | Compatible |
| PLA (four-way cassette) | PLA-A…EA has CN105 PLA-A…AE has CN105 PLA-A…BA4/BA6 has CN105 PLA-A…AA no CN105 PLA-A…BA/BA1 no CN105 · The EA and AE trims and BA4/BA6 have CN105; the AA trims and the base BA/BA1 do not, per Mitsubishi's official P-Series controls compatibility table | Check suffix |
| PEA (horizontal ducted) | PEA-A…AA4/AA4R1/AA6 has CN105 PEA-A…AA no CN105 · AA4, AA4R1 and AA6 have CN105; the base AA does not, per Mitsubishi's official P-Series controls compatibility table | Check suffix |
| PEA-RP (EA trims) | PEA-RP140EA2 · EU, AU, Asia · Has CN105 and answers at 9600 baud instead of 2400. On HomeKit-compatible and Matter-compatible firmware, set CN105 Baud Rate to 9600 under Device > Advanced in the web interface. On ESPHome, set baud_rate to 9600 in the uart block of your YAML | Compatible |
| PAA (intelli-HEAT) | PAA-A · Both the AA and NL trims have CN105, per Mitsubishi's official P-Series controls compatibility table | Compatible |

**CITY MULTI / S / Y / R2 / HVRF**

| Series | Examples & notes | Verdict |
| --- | --- | --- |
| PCFY-NKMU-ER2.TH | PCFY-P15NKMU-ER2.TH PCFY-P24NKMU-ER2.TH PCFY-P36NKMU-ER2.TH · All four audited capacities are compatible per their LinkDrive Controls pages | Compatible |
| PEFY-NMAU-E3/E4/E5 and PEFY-NMHSU | PEFY-P06NMAU-E3 PEFY-P27NMAU-E3 PEFY-P96NMHSU-E · 26 exact audited models are direct-CN105 compatible | Compatible |
| PEFY-NMHU-E2 | PEFY-P15NMHU-E2 PEFY-P30NMHU-E2 PEFY-P54NMHU-E2 · All eight capacities connect to CN105 directly, with no adapter | Compatible |
| PKFY-NLMU, NKMU-E2R1.TH, NGMU-E | PKFY-P04NLMU-E PKFY-P12NLMU-ER1.TH PKFY-P30NKMU-E2R1.TH · 16 exact audited models are direct-CN105 compatible | Compatible |
| PLFY-NEMU/NEMU1/NFMU and NBMU-E2 | PLFY-EP06NEMU-E PLFY-EP48NEMU-ER1 PLFY-P48NEMU-E · 53 exact audited models are direct-CN105 compatible | Compatible |
| PMFY-NBMU-ER6 | PMFY-P06NBMU-ER6 PMFY-P15NBMU-ER6 · All four audited capacities list the qualifying CN105 controls | Compatible |
| PVFY-NAMU | PVFY-P08NAMU-E1 PVFY-P30NAMU-E PVFY-P54NAMU-E1 · 15 exact audited NAMU models are direct-CN105 compatible | Compatible |
| PCFY-NKMU-ER1 | PCFY-P15NKMU-ER1 PCFY-P36NKMU-ER1 · Requires PAC-IT51AD-E or PAC-IT52AD-E and the table's manufacturing-date check; not a direct CN105 connection | Adapter |
| PEFY-NMAU-E2 and NMSU-ER2 | PEFY-P06NMAU-E2 PEFY-P54NMAU-E2 PEFY-P24NMSU-ER2 · 17 exact models require a Mitsubishi adapter and the applicable manufacturing-date check | Adapter |
| PFFY-NEMU/NRMU-E | PFFY-P06NEMU-E PFFY-P15NEMU-E PFFY-P24NRMU-E · All 12 audited models require a Mitsubishi adapter and the applicable manufacturing-date check | Adapter |
| PKFY-NBMU/NHMU/NKMU adapter revisions | PKFY-P06NBMU-E2 PKFY-P18NHMU-E2 PKFY-P30NKMU-E2.TH · Ten exact models require a Mitsubishi adapter and the applicable manufacturing-date check | Adapter |
| PLFY-NCMU-ER4 and NBMU-ER2 | PLFY-P08NCMU-ER4 PLFY-P15NCMU-ER4 PLFY-P36NBMU-ER2 · Nine exact models require a Mitsubishi adapter and the applicable manufacturing-date check | Adapter |
| PMFY-NBMU-ER5 | PMFY-P06NBMU-ER5 PMFY-P15NBMU-ER5 · All four audited capacities require a Mitsubishi adapter and the applicable manufacturing-date check | Adapter |
| PCFY-NGMU-E and NKMU-E/E.TH | PCFY-P15NGMU-E PCFY-P30NGMU-E PCFY-P36NKMU-E.TH · All 12 exact revisions are marked NO in the official CITY MULTI Controls table | Not compatible |
| PEFY-NMAU/NMLU/NMSU/NMHU base E revisions | PEFY-P06NMAU-E PEFY-P24NMAU-E PEFY-P96NMHU-E · All 30 exact revisions are marked NO in the official CITY MULTI Controls table | Not compatible |
| PKFY-NAMU/NBMU/NFMU/NHMU/NKMU base E revisions | PKFY-P06NAMU-E PKFY-P18NFMU-E PKFY-P30NKMU-E · All 12 exact revisions are marked NO in the official CITY MULTI Controls table | Not compatible |
| PLFY-NAMU/NBMU/NCMU/NLMU base revisions | PLFY-12NAMU-A PLFY-P15NAMU-E PLFY-P36NBMU-E · All 25 exact revisions are marked NO in the official CITY MULTI Controls table | Not compatible |
| PMFY-NBMU-E | PMFY-P06NBMU-E PMFY-P15NBMU-E · All four audited capacities are marked NO in the official CITY MULTI Controls table | Not compatible |
| PVFY-E00 | PVFY-P12E00A PVFY-P30E00B PVFY-P54E00B · All 14 exact E00 models are marked NO in the official CITY MULTI Controls table | Not compatible |
| PDFY-NMU-E | PDFY-P06NMU-E PDFY-P24NMU-E PDFY-P48NMU-E · The table names PEFY rather than PDFY and the product Controls pages have no qualifying entry; compatibility is not established | Check CN105 |
| PEFY-WL HVRF | PEFY-WL06NMAU-A PEFY-WL24NMAU-A PEFY-WL48NMAU-A · No governing U.S. HVRF Controls table or qualifying product-page entry was found | Check CN105 |
| PKFY-WL HVRF | PKFY-WL04NLMU-E.TH PKFY-WL15NLMU-E.TH PKFY-WL30NKMU-E.TH · No governing U.S. HVRF Controls table or qualifying product-page entry was found | Check CN105 |
| PLFY-WL HVRF | PLFY-WL04NFMU-E.TH PLFY-WL15NEMU-E.TH PLFY-WL48NEMU-E.TH · No governing U.S. HVRF Controls table or qualifying product-page entry was found | Check CN105 |
| PWFY-NMU hydronic | PWFY-P36NMU-E-AU PWFY-P36NMU-E2-AU PWFY-P72NMU-E2-AU · The table has no PWFY column and the product Controls pages have no qualifying entry | Check CN105 |

**Trane / American Standard**

| Series | Examples & notes | Verdict |
| --- | --- | --- |
| NAXWST, NTXWPH, NTXWST, NTYWST | NAXWST09A112AB NTXWPH09B112AA NTXWST12A112AA NTYWST12A112AA · Same hardware as Mitsubishi; confirmed compatible. NTXWST/NTYWST A112AA indoor boards have CN105 per Trane service manual OBHT732 | Compatible |
| NTXWMT, NTXWEL | NTXWMT12A112AB NTXWMT09A111AB NTXWEL12A112AA NTXWEL24A112AA · Trane builds of MSZ-HM, MSZ-JP (NTXWMT) and MSZ-WR (NTXWEL); every trim's Trane LinkDrive page lists the MHK2 controller | Compatible |
| NTXCKS, NTXUKS, NTXDKS, NTXFKS, NTXAMT | NTXCKS12A112BA NTXUKS09A112BA NTXDKS12A112AA NTXFKS12A112AA NTXAMT24A112AA · Trane builds of SLZ-KF, MLZ-KP/KY, SEZ-KD NA4, MFZ-KJ and SVZ-KP; every trim's Trane LinkDrive page lists the MHK2 controller | Compatible |
| TPKA, TPCA, TPLA, TPEADA, TPVA | TPKA0A0241KA80A TPCA0A0241KA80A TPLA0A0241EA80A TPEADA0121AA80A TPVA0A0241AA70A · Trane P-Series builds of PKA, PCA, PLA, PEAD and PVA; each maps to a compatible Mitsubishi trim | Compatible |
| TPCFYP, TPEFYP, TPFFYP, TPKFYP, TPLFYP, TPMFYP, TPVFYP | TPLFYP012EM140B has CN105 TPEFYP006MA144A has CN105 TPKFYP004LM140B has CN105 TPEFYP006MS140C no CN105 TPFFYP006RE140A no CN105 TPKFYP024KM142A no CN105 · Trane CITY MULTI builds take the answer of the exact Mitsubishi revision behind them; several need a PAC-IT51AD-E or PAC-IT52AD-E signal adapter | Check suffix |
| TPEFYW, TPKFYW, TPLFYW, TPWFYP | TPEFYW006MA1W0A TPLFYW04FM1W0A TPWFYP036AU141A · Trane builds of the HVRF and PWFY units, which no Controls table or product page settles | Check CN105 |

## Feature availability

All compatible units support basic climate control (mode, temperature, fan speed). Some advanced features vary by model.

| Feature | Notes | Availability |
| --- | --- | --- |
| Climate control (mode, temp, fan) | Core functionality; always works | All models |
| Vertical vane | Not applicable to ducted units | Most wall-mount units |
| Horizontal vane (wide vane) | Not all models have motorized horizontal vanes | Some wall-mount units |
| Outside air temperature | Depends on outdoor unit; may report -63.5°C when compressor is idle (normal). Not available on some multi-zone configurations. | Many models |
| Compressor frequency | Often unavailable on multi-split systems. Some models always report 0. | Many single-zone systems |
| Input power (W) & energy (kWh) | Varies significantly by model. Available on some MSZ-GS, MSZ-HR, MSZ-LN, MSZ-WX models. Not available on many others. | Some models |
| Runtime hours | Available on select models | Some models |
| i-See sensor | Sensor data readable on supported models; direct control not yet available | Models with i-See hardware |
| Remote temperature sensor | Override the unit's internal temperature reading with an external sensor (Home Assistant sensor for ESPHome, BLE sensor for HomeKit) | Most models |

---

Compatibility information is based on community reports, manufacturer documentation, and open-source project data. It may not be exhaustive and is not guaranteed for every unit; always verify both that your model is listed as supported and that a CN105 connector is present on your unit before buying hardware.
